APPENDIX B. SAMPLE RUNSTREAMS


B.1. Configuration Routine

WELCOME TO |This is the header |with title page |skip OFF SSSSS TTTTTTTT AAA GGGGG |(See below). SS SS TTTTTTTT A A GGGGGGG | SS TT AA AA GG | SSSSS TT AAAAAAA GG GGG | SS TT AA AA GG G | SS SS TT AA AA GGGGGGG | SSSSS TT AA AA GGGGG | | The STAnd Generator for mixed conifers | | version 4.4A | | (c) Copyright 1984-1994 The Regents of The University of California | | | enter "return" to continue |[Whenever simply |entering a "carriage The STAnd Generator for mixed conifers |return" accomplishes |our goal, its entry by |is implied]. Greg S. Biging, Lee C. Wensel, | Walter J. Meerschaert, Paul C. Van Deusen, Timothy A. Robards, | and Eric C. Turnblom | Department of Forestry and Resource Management | University of California, Berkeley | | A Product of the Northern California Forest Yield Coop. | | American Forest Products The Hearst Corp. | W.M. Beaty and Associates, Inc. Louisiana-Pacific Corp. (Elk Creek) | Champion International Corp. Louisiana-Pacific Corp. (Feather Falls) | Crane Mills Michigan-California Lumber Co. | Fibreboard Corporation Pacific Gas & Electric Co. | Fruit Growers Supply Co. Roseburg Resources Co. (Diamond Lands) | Georgia Pacific Corp. (Martell) Sierra Pacific Industries | | U.S.D.A. Forest Service (R5) CA Dept. of Forestry & Fire Protection | | Research conducted under AES project 3679-MS. | | | enter "return" to continue | MAIN PROGRAM | ------------ | Type "pc" to get a list of commands | | | | | stag: cf |Enter the |configuration CONFIGURATION ROUTINE |routine (responses ------------- ------- |the user would type |appear in bold Type "pc" to get a list of available commands. |characters). | - CURRENT CONFIGURATION STATUS - | | re - Add random errors.....................ON |Current Height coefficients...................DEFAULT |status is printed sk - Title page skip.......................OFF |automatically. | dc - DBH class width used in d.a........... 2.0" | mr - Max. number of records in d.a......... 500 | cm - Cubic minimum diameter................ .0" | ct - Cubic merch top....................... 4.0" | bm - Board foot minimum diameter........... 8.0" | bt - Board foot merch top.................. 6.0" | hc - Highlight Code........................ 3 | ro - stand description read option......... 0 | jh - join under/overstory height models....NO | uc - auto. understory compression..........ON | ur - understory compression ratio.......... .5 | | | config: pc |Print available |commands. CONFIGURATION COMMANDS | ============= ======== | bm - set board foot minimum DBH | bt - set board foor merchantable top | cm - set cubic foot minimum DBH | ct - set cubic foot merchantable top | dc - set DBH class width used in "distributional apportionment" | ex - exit configuration routine | hc - set highlight codes for displaying tree lists | jh - set under/overstory height model joining | mr - set max. number of records created in "distributional apportionment" | pc - print commands | ps - print current configuration status | rc - reset to default configuration parameters | re - set flag to add random errors to predictions | rh - reset to default height equation parameters | ro - set stand description read option | sc - save current configuration | sk - set title page skip |These options uc - set automatic understory tree record compression |are for routines ur - set ratio of tree records saved in "ug" (overstory:understory) |that use files. | OPTIONS: [>or>>output] [{input] | | config: bm |Set minimum DBH Board foot min. DBH = 8.0 enter new: 8.0 |contributing to board |foot volume. config: bt | Board foot merch top = 6 in.- enter new (6 or 8): 6 |Set merchantable top |diameter for board config: cm |foot volume. Cubic min. DBH = .0 enter new; | (must be less than board ft DBH min.): 4.0 |Set minimum and |merchantable diameters config: ct |for cubic foot volume Cubic merch top = 4 in. - Enter new (4 or 6): 4 |analogously. | config: mr |Set the maximum number Maximum number of records produced in dist. app. is 500 |of records produced in Enter new maximum (100-500): 100 |distributional apportionment. | config: re |In this example, we want Current random error flag is set to 1 |to make sure random Enter new flag value (1=add random errors, 0=don't): 1 |errors are added to |height and crown estimates. config: sk | Title page skip is currently 0 enter new (0=print, 1=skip): 1 |Set the title page |skip for future runs. config: ur |Ratio of overstory to The ratio of the number of overstory tree records to the number of understory |understory tree records tree records is .5 - enter new value (0.1 - 4.0): 1.0 |desired is 1:1. | config: uc |Turn off automatic Automatic understory tree record compression is ON. |invocation of under- Enter new setting (0=OFF, 1=ON): 0 |story collapsing |algorithm. config: ps | - CURRENT CONFIGURATION STATUS - |Print status of the |new configuration to re - Add random errors.....................ON |check our choices. Height coefficients...................DEFAULT | sk - Title page skip.......................ON | dc - DBH class width used in d.a........... 2.0" | mr - Max. number of records in d.a......... 100 | cm - Cubic minimum diameter................ 4.0" | ct - Cubic merch top....................... 4.0" | bm - Board foot minimum diameter........... 8.0" | bt - Board foot merch top.................. 6.0" | hc - Highlight Code........................ 3 | ro - stand description read option......... 0 | jh - join under/overstory height models....NO | uc - auto. understory compression..........OFF | ur - understory compression ratio.......... 1.0 | | |Save the current config: sv |configuration in Current configuration saved in: stbin |the reserved STAG |file named "STBIN." | config: ex | Exiting initialization routine | | | stag: ex | stag: user termination |
| HOME |FEEDBACK