SiteDateAuthorSummary
Tonzi (148) 2025-05-28 11:00:00 Joe Verfaillie Kuno's last round of chamber fluxes for a while, standard data collection, trouble getting all the GPS data, zcam1 tilted, ground IRT out of mount, pressure bomb leaking, Moisture Point dying
Tonzi (135) 2025-05-15 10:15:00 Joe Verfaillie Deleted a couple days of GPS data, well meter dead battery, Reinstalled soil water potential C but data still bad - program problem? Midday leaf water potential.
Tonzi (125) 2025-05-05 12:00:00 Will Riley Rob Rhew's lab come to do H2 static chamber measurements late in the day.
Tonzi (119) 2025-04-29 09:30:00 Joe Verfaillie Collected GPS data, Swapped 7500s, failed to swap Tower 7700, Standard data collection, fixed tower fence, stole battery, replaced Floor RH/T fan.
Tonzi (107) 2025-04-17 10:00:00 Joe Verfaillie Kuno and visitor doing chamber work and swapped Floor 7700
Tonzi (100) 2025-04-10 10:00:00 Joe Verfaillie Housen collect first batch of GPS data, Kuno doing standard chamber fluxes, Mihkel visiting the site, removed Theta 7, nearly fully leafed out.
Tonzi (86) 2025-03-27 08:00:00 Joe Verfaillie Standard field work, mostly leafed out, first midday water potential of the year, Housen installed GPS units, Theta probe 7 needs to be dug up.
Tonzi (70) 2025-03-11 10:45:00 Joe Verfaillie Standard data collection, Kuno added twig flux, Installed FD from Vaira at tree1 and move FD back to open, garter snake, pulled Under moisture point probe.
Tonzi (52) 2025-02-21 10:50:00 Joe Verfaillie Phenocam images went missing, Replaced North T3 TC on tree stem temps, Removed Tree1 FD due to bad CO2 reading replaced with open FD, IRT tilted, zcam1 tilted, Tower fence fixed.
Tonzi (38) 2025-02-07 11:10:00 Joe Verfaillie Wet after rains, Floor 7700 lst line lock, flushed and refreshed optics desiccant, #3 TC on north bole temp tree not working, Under Moisture Point broken, updated RevBowen code.
Tonzi (22) 2025-01-22 11:20:00 Joe Verfaillie Mild and dry, standard fieldwork, not much happening, reset tree 5 dendrometer, removed old co2 profile solenoid box, tried to update RevBowen code on floor and tower met.
Tonzi (9) 2025-01-09 10:50:00 Joe Verfaillie Floor power seems okay, swapped IRGAs for calibration, collected point dendrometer data, reinstalled bottom GMP343, Tree/soil chambers, N2 tank removed